Font Size:
Failure analysis of flexible couplings by self-heating
Last modified: 10. 05. 2023
Abstract
Flexible couplings are applied in mechanical systems to reduce torsional vibrations. Failures in the flexible parts of the couplings are often incorrectly attributed to overloading of the couplings. The goal of the article is to prove by experimental analysis that self-heating occurs in flexible couplings. The self-heating of the flexible coupling and the consequent increase in the temperature of the flexible part is the cause of the failure. Experimental identification of self-heating was performed on three types of flexible couplings. Although these couplings are design different, they are used for a nominal torque of 150Nm.